Bard EIFM-3C Specifications

Browse online or download Specifications for Split-system air conditioners Bard EIFM-3C. Bard EIFM-3C Specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Date: 03-05-14

Manual 2100-588APage 1 of 29INSTALLATION INSTRUCTIONSWALL MOUNTED PACKAGE AIR CONDITIONERSMODELS J17A2 J17L2 J24A2 J24L2 J30A2 J30L2 J36A2

Page 2 - Contents

Manual 2100-588A Page 10 of 29FIGURE 3CJ42A2, J42L2, J48A2, J48L2, J60A2, J60L2, J70A2, J70L2MOUNTING INSTRUCTIONSD16"16"16"16"1

Page 3 - THESE PUBLISHERS:

Manual 2100-588A Page 11 of 29FIGURE 4ELECTRIC HEAT CLEARANCEJ30A2, J30L2, J36A2, J36L2, J42A2, J42L2, J48A2, J48L2, J60A2, J60L2, J70A2, J70L2

Page 4 - SHIPPING DAMAGE

Manual 2100-588A Page 12 of 29FIGURE 5WALL MOUNTING INSTRUCTIONSFIGURE 6WALL MOUNTING INSTRUCTIONSDUCTOPENINGRETURN AIRSUPPLY AIRWOOD FRAME WALL IN

Page 5 - CONDENSATE DRAIN

Manual 2100-588A Page 13 of 29FIGURE 7COMMON WALL MOUNTING INSTALLATIONSLOWEREDRAISED FLOORRAFTERSSUPPLY AIRCEILING SURFACEWALL SLEEVERETURN AIRCLOS

Page 6

Manual 2100-588A Page 14 of 29WIRING – MAIN POWERRefer to the unit rating plate for wire sizing information and maximum fuse or “HACR” type circuit

Page 7 - Page 7 of 29

Manual 2100-588A Page 15 of 29FIGURE 8BASIC A/C with OPTIONAL ELECTRIC HEATNO ECONOMIZERGTERMINAL BLOCKA2Y2 W1E3RC Y Y11W2UNIT 24VFOPEN OR SPECIAL U

Page 8 - J17A2, J17L2, J24A2, J24L2

Manual 2100-588A Page 16 of 29FIGURE 9BASIC A/C with OPTIONAL ELECTRIC HEATOLDER EIFM STYLE ECONOMIZERA12C W1GWIRING HARNESSTERMINAL BLOCKY1EIFM ECO

Page 9 - J30A2, J30L2, J36A2, J36L2

Manual 2100-588A Page 17 of 29FIGURE 10BASIC A/C with OPTIONAL ELECTRIC HEATNEWER ECONWM* STYLE ECONOMIZERYFACTORY INSTALLED JUMPER FOR IMMEDIATE EM

Page 10 - MOUNTING INSTRUCTIONS

Manual 2100-588A Page 18 of 29START UPTHESE UNITS REQUIRE R-410A REFRIGERANT AND POLYOL ESTER OIL.GENERAL:1. Use separate service equipment to avoid

Page 11 - WARNING

Manual 2100-588A Page 19 of 29START UP (Continued)IMPORTANT INSTALLER NOTEFor improved start up performance wash the indoor coil with a dish washing

Page 12 - WALL MOUNTING INSTRUCTIONS

Manual 2100-588A Page 2 of 29ContentsFiguresFigure 1 Fresh Air Damper Assembly ...5Figure 2 Unit Dimensions ...

Page 13 - FREE AIR FLOW

Manual 2100-588A Page 20 of 29SEQUENCE OF OPERATIONCOOLING – Circuit R-Y makes at thermostat pulling in compressor contactor, starting the compress

Page 14 - WIRING – MAIN POWER

Manual 2100-588A Page 21 of 29TROUBLESHOOTINGFIGURE 11FAN BLADE SETTINGTABLE 1FAN BLADE DIMENSIONR-410AREFRIGERANT CHARGEThis unit was charged at t

Page 15 - NO ECONOMIZER

Manual 2100-588A Page 22 of 29TABLE 4 COOLING PRESSURE TABLEAir Temperature Entering Outdoor Coil °FLow side pressure ± 4 PSIG

Page 16 - OLDER EIFM STYLE ECONOMIZER

Manual 2100-588A Page 23 of 29TABLE 5j Maximum size of the time delay fuse or HACR type circuit breaker for protection of eld wiring conductors.

Page 17 - FIGURE 10

Manual 2100-588A Page 24 of 29TABLE 6j Maximum size of the time delay fuse or HACR type circuit breaker for protection of eld wiring conductors.

Page 18 - WARNING

Manual 2100-588A Page 25 of 29TABLE 7RECOMMENDED AIRFLOWTABLE 8INDOOR BLOWER PERFORMANCETABLE 9MAXIMUM ESP OF OPERATION ELECTRIC HEAT ONLYValues s

Page 19 - START UP (Continued)

Manual 2100-588A Page 26 of 29TABLE 10ELECTRIC HEATModels 240V-1 208V-1 240V-3 208V-3 460V-3KW Amps BTUH Amps BTUH Amps BTUH Amps BTUH Amps BTUH4 16

Page 20 - PRESSURE SERVICE PORTS

Manual 2100-588A Page 27 of 29Manual 2100-581A Page 27 of 26J17A2-AJ24A2-AJ24A2-BJ24A2-CJ30A2-AJ30A2-BJ30A2-CJ36A2-AJ36A2-BJ36A2-CJ42A2-AJ42A2-BJ42A

Page 21 - TROUBLESHOOTING

Manual 2100-588A Page 28 of 29TABLE 11BOPTIONAL ACCESSORIES — LEFT HANDJ17L2-AJ24L2-AJ24L2-BJ30L2-AJ30L2-BJ30L2-CJ36L2-AJ36L2-BJ36L2-CJ42L2-AJ42L2-B

Page 22 - COOLING PRESSURE TABLE

Manual 2100-588A Page 29 of 29TABLE 12VENT & CONTROL OPTIONSJ17, J24W30, J36J42, J48, J60, J70Part Number DescriptionBFAD-2 Barometric Fresh Air

Page 23 - TABLE 5

Manual 2100-588A Page 3 of 29GETTING OTHER INFORMATION AND PUBLICATIONSThese publications can help you install the air conditioner or heat pump. You

Page 24 - TABLE 6

Manual 2100-588A Page 4 of 29WALL MOUNT GENERAL INFORMATIONAIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE J 42 A 2 – A 10 X X X X X J

Page 25 - Page 25 of 29

Manual 2100-588A Page 5 of 29DUCT WORKAll duct work, supply and return, must be properly sized for the design airow requirement of the equipment. A

Page 26 - ELECTRIC HEAT

Manual 2100-588A Page 6 of 29Clearances Required for Service Access and Adequate Condenser AirowMODELSLEFTSIDERIGHTSIDEDISCHARGE SIDEJ17A, J24A, J30

Page 27 - PULL DISCONNECT (WMPD)

Manual 2100-588A Page 7 of 29Dimensions of Basic Unit for Architectural and Installation Requirements (Nominal)MODELWIDTH(W)DEPTH(D)HEIGHT(H)SUPPLY R

Page 28 - TABLE 11B

Manual 2100-588A Page 8 of 29FIGURE 3AJ17A2, J17L2, J24A2, J24L2MOUNTING INSTRUCTIONS12"12"12"12"12"20"20"1"

Page 29 - VENT & CONTROL OPTIONS

Manual 2100-588A Page 9 of 29FIGURE 3BJ30A2, J30L2, J36A2, J36L2MOUNTING INSTRUCTIONS28" A CDC12"12"12"12"12" 5116&quo

Comments to this Manuals