Bard WA4823 User Manual

Browse online or download User Manual for Conditioners Bard WA4823. Bard WA4823 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 21
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTALLATION INSTRUCTIONS
WALL MOUNTED
PACKAGE AIR CONDITIONERS
MODELS
WA4822
WA4823
WA6022
WA6023
WA602N
Manual : 2100-348D
Supersedes: 2100-348C
File: Volume III Tab 16
Date: 05-20-01
Bard Manufacturing Company
Bryan, Ohio 43506
Since 1914...Moving ahead just as planned.
© Copyright 2001
Page view 0
1 2 3 4 5 6 ... 20 21

Summary of Contents

Page 1 - Bryan, Ohio 43506

INSTALLATION INSTRUCTIONSWALL MOUNTEDPACKAGE AIR CONDITIONERSMODELSWA4822WA4823WA6022WA6023WA602NManual : 2100-348DSupersedes: 2100-348CFile: Volume I

Page 2 - CONTENTS

Manual 2100-348Page 8FIGURE 3MOUNTING INSTRUCTIONSWA602N, WA6023, WA4823 ONLYMIS-1349

Page 3 - Page 1

Manual 2100-348Page 9FIGURE 4MOUNTING INSTRUCTIONSWA6022, WA4822 ONLYMIS-1444

Page 4 - ELECTRIC HEAT TABLE

Manual 2100-348Page 10FIGURE 5ELECTRIC HEAT CLEARANCESIDE SECTION VIEW OF SUPPLY AIR DUCT FOR WALLMOUNTED UNIT SHOWING 1/4 INCH CLEARANCE TOCOMBUS

Page 5 - UNIT DIMENSIONS

Manual 2100-348Page 11FIGURE 6WALL MOUNTING INSTRUCTIONSFIGURE 7WALL MOUNTING INSTRUCTIONSMIS-548MIS-549SEE FIGURE 3 – MOUNTING INSTRUCTIONSSU

Page 6 - FIGURE 2

Manual 2100-348Page 12FIGURE 8COMMON WALL MOUNTING INSTALLATIONSFREE AIR FLOW NO DUCTDUCTED SUPPLY RETURN AT UNITFALSE WALL INSTALLATIONCLOSET I

Page 7 - Page 5

Manual 2100-348Page 13WIRING – MAIN POWERRefer to the unit rating plate for wire sizing informationand maximum fuse or “HACR” type circuit brea

Page 8 - SHIPPING DAMAGE

Manual 2100-348Page 14FIGURE 9UNIT 24V TERMINAL BOARDMIS-1373A

Page 9 - WARNING

Manual 2100-348Page 15START UPIMPORTANT INSTALLER NOTEFor improved start up performance wash the indoor coilwith a dish washing detergent.CRANKCA

Page 10 - MOUNTING INSTRUCTIONS

Manual 2100-348Page 16PRESSURE SERVICE PORTSHigh and low pressure service ports are installed on allunits so that the system operating pressures ca

Page 11 - WA6022, WA4822 ONLY

Manual 2100-348Page 17The suction line temperatures in table above are basedupon 80° F dry bulb / 67° F wet bulb (50% R.H.)temperature and rated

Page 12 - WARNING

CONTENTSFiguresFigure 1 Unit Dimensions ... 3WA602N, WA6023, WA4823Figure 2 Unit Dimensions ...

Page 13 - WALL MOUNTING INSTRUCTIONS

Manual 2100-348Page 18Low side pressure ± 2 PSIGHigh side pressure ± 5 PSIGTables are based upon rated CFM (airflow) across the evaporator coil.

Page 14 - Page 12

Manual 2100-348Page 19TABLE 11OPTIONAL ACCESSORIESWA6023A. WA6022AWA6023B, WA6022BWA4823A, WA4822AWA4823B, WA4822BtraPrebmuNnoitpircseD51-CMCtiK

Page 15 - WIRING – LOW VOLTAGE WIRING

Manual 2100-348Page 1Getting Other Information and PublicationsThese publications can help you install the air conditioneror heat pump. You can u

Page 16 - MIS-1373A

Manual 2100-348Page 2WALL MOUNT GENERAL INFORMATIONAIR CONDITIONING WALL MOUNT MODEL NOMENCLATUREWA 60 2 3 A 10 X N X X

Page 17 - START UP

Manual 2100-348Page 3FIGURE 1UNIT DIMENSIONSWA602N, WA6023, WA4823 ONLYMIS-1348

Page 18 - ADJUSTMENTS

Manual 2100-348Page 4FIGURE 2UNIT DIMENSIONSWA6022, WA4822 ONLYMIS-1442

Page 19 - TROUBLESHOOTING

Manual 2100-348Page 5TABLE 2ELECTRICAL SPECIFICATIONSjklMaximum size of the time delay fuse or HACR type circuit breaker for protection of field

Page 20

Manual 2100-348Page 6A 1/4 inch clearance to combustible material for the firstthree feet of duct attached to the outlet air frame isrequired. See

Page 21 - OPTIONAL ACCESSORIES

Manual 2100-348Page 7INSTALLATION INSTRUCTIONSWALL MOUNTING INFORMATION1. Two holes for the supply and return air openings mustbe cut through th

Related models: WA4822 | WA6023 |

Comments to this Manuals

No comments